Florida Certified EC13004667Veteran-OwnedNo-Commission Electricians

Commercial Backup Generators in Jacksonville

When the grid goes down, your business shouldn’t. Empire Electric sizes, installs and maintains commercial standby generators, including three-phase generators, automatic transfer switches and the power distribution behind them, for businesses across Jacksonville and Northeast Florida.

Commercial Backup Standby Generators
Licensed Contractor

Florida Certified EC13004667

Insured

$2 million policy

Three-Phase Power

Generators and distribution

Permits Handled

Pulled and inspected

Upfront Pricing

Written, flat-rate estimates

24/7 Emergency

Generator down? We respond

Standby Power for Every Business

Every business has different critical loads. Choose yours to see what we typically back up.

Restaurants and Food Service

Keep coolers, freezers, kitchen equipment and POS systems running so inventory doesn’t spoil.

Warehouses and Manufacturing

Three-phase standby power for production lines, conveyors, cold storage and critical controls.

Offices and Data Rooms

Protect servers, phones, security and access control, and keep your team working.

Gas Stations and Convenience Stores

Florida law requires many fuel stations to be prewired with a transfer switch for generator power. We install them.

Hurricane season runs June through November.

Generators, transfer switches and permits take time. Plan your standby power before the next storm, not after.

How Commercial Generators Differ

A home generator and a commercial standby system solve the same problem at very different scales. Here’s what changes when you’re powering a business.

ResidentialCommercial
Electrical serviceSingle-phase, 120/240 voltsSingle-phase or three-phase, commonly 208Y/120 or 480Y/277 volts
Generator sizeSized for a house: essentials or the whole homeSized from a load study of the building's equipment, often much larger
FuelNatural gas or propaneNatural gas, propane or diesel with on-site fuel storage
Transfer switchOne automatic transfer switch at the home's panelOne or more automatic transfer switches, often separating critical and non-critical loads
Power distributionFeeds the home's main panelFeeds switchgear, distribution panels, subpanels and transformers
Code categoryOptional standby (NEC Article 702)Optional standby, or emergency and legally required systems (NEC 700 and 701) when required
TestingAutomatic exercise per the manufacturerScheduled exercise and testing; required systems follow NFPA 110
InstallationConcrete pad beside the housePad or enclosure sized to the unit, fuel supply, conduit runs and sometimes crane placement

Looking for a generator for your home?

Three-Phase Standby Power, Start to Finish

Most commercial buildings run on three-phase power, and their motors, compressors, HVAC and production equipment need it. We install three-phase generators matched to your service voltage, then build the distribution that gets backup power where it needs to go.

Matched to your service

Which Kind of Standby System Do You Need?

The National Electrical Code sorts backup power into three categories. The category sets how fast power must return and how the system is wired, tested and maintained. We’ll help you determine what applies.

Emergency Systems

Required by code to protect lives: egress lighting, exit signs, fire alarms, fire pumps and similar loads.

NEC Article 700 · power within 10 seconds

Legally Required Standby

Required by code to prevent hazards or support rescue: ventilation, smoke removal, sewage and critical processes.

NEC Article 701 · power within 60 seconds

Optional Standby

Chosen by the business to avoid lost revenue and spoiled inventory: refrigeration, HVAC, data and operations.

NEC Article 702 · most business generators

Commercial Generator Services

Three-Phase Standby Generators

Automatic Transfer Switches

Manual Transfer and Docking Stations

Distribution Panels and Switchgear

Subpanels, Feeders and Transformers

Load Shedding and Priority Circuits

Natural Gas and Propane Generators

Diesel Generators

Gas Station Transfer Switch Prewiring

Load Bank Testing and Maintenance

The Real Cost of Downtime

Lost sales, idle staff and spoiled inventory add up fast. Run your own numbers to see what a few outages a year really cost your business.

Then compare that with a standby generator that turns your power back on automatically, in seconds.

What Does a Power Outage Cost You?

Enter your own numbers. The results update as you type.

–cost of one outage
–estimated cost per year

A simple estimate from your inputs. It doesn't include harder-to-measure costs like lost customers, data loss or equipment damage from power surges when the grid returns.

Our Commercial Generator Process

01

Load Study

We review your service, equipment and which loads must stay on.

02

Sizing and Design

Generator size, voltage, fuel, transfer switches and distribution planned.

03

Upfront Price

You get a written, flat-rate price for the complete system.

04

Permits and Coordination

We pull permits and coordinate fuel, pad and utility requirements.

05

Installation

Generator, transfer switches, feeders and distribution installed.

06

Commissioning and Testing

Startup, transfer testing under load and a walkthrough for your staff.

Generator Maintenance and Testing

A generator that won’t start during an outage is worth nothing. Regular testing and service keep it ready.

Scheduled Exercise

Generators need to run regularly. NFPA 110 calls for monthly exercise of at least 30 minutes for systems that fall under it.

Load Bank Testing

Generators that run lightly loaded during exercise can be tested with a load bank to prove they’ll carry the building.

Transfer Switch Service

We inspect and test automatic transfer switches so the handoff happens when the power fails.

Commercial Standby Power You Can Count On

Generators and Distribution Under One Roof

We handle the generator, transfer switches and every panel, feeder and transformer behind them, so nothing falls between contractors.

Licensed and Insured

Florida State Certified Electrical Contractor EC13004667 with a $2 million insurance policy and a Jacksonville office.

Upfront Pricing and a Warranty

Written, flat-rate pricing before work begins and a five-year warranty on our workmanship.

Commercial Generator Questions

Can you install three-phase generators?

Yes. We install three-phase standby generators matched to your service, commonly 208Y/120 or 480Y/277 volts, along with the transfer switches and distribution they connect to.

What's the difference between a home and commercial generator?

Commercial systems are usually larger, often three-phase, may run on diesel as well as gas, and can include multiple transfer switches and distribution panels. Some commercial systems are also required by code and must meet stricter testing rules.

What size generator does my business need?

It depends on the equipment you need to keep running. We start with a load study of your service and critical equipment, then size the generator and transfer switches to match.

Can a generator back up only part of my building?

Yes. Many businesses back up only critical loads such as refrigeration, servers, security and some lighting. We separate those circuits so a smaller generator can carry them.

Does my gas station need a generator transfer switch?

Florida law requires many motor fuel stations, including newer or substantially renovated stations and certain stations near evacuation routes, to be prewired with a transfer switch for generator power. Call us and we’ll review your site.

How often should a commercial generator be tested?

Regularly. For systems that fall under NFPA 110, that means monthly exercise of at least 30 minutes, plus scheduled maintenance. We can set up a testing and maintenance plan.

Keep Your Business Powered

Call or request a free estimate online. We’ll study your loads and design a standby system with a written, upfront price.

(904) 365-7777

service@empireelec.com

Office

5810 Macy Ave, Jacksonville, FL 32211

Hours

Mon–Fri, 8:00 am–4:00 pm · 24/7 emergency service