When the grid goes down, your business shouldn’t. Empire Electric sizes, installs and maintains commercial standby generators, including three-phase generators, automatic transfer switches and the power distribution behind them, for businesses across Jacksonville and Northeast Florida.

Florida Certified EC13004667
$2 million policy
Generators and distribution
Pulled and inspected
Written, flat-rate estimates
Generator down? We respond
Every business has different critical loads. Choose yours to see what we typically back up.
Keep coolers, freezers, kitchen equipment and POS systems running so inventory doesn’t spoil.
Three-phase standby power for production lines, conveyors, cold storage and critical controls.
Protect servers, phones, security and access control, and keep your team working.
Florida law requires many fuel stations to be prewired with a transfer switch for generator power. We install them.
Generators, transfer switches and permits take time. Plan your standby power before the next storm, not after.
A home generator and a commercial standby system solve the same problem at very different scales. Here’s what changes when you’re powering a business.
| Residential | Commercial | |
|---|---|---|
| Electrical service | Single-phase, 120/240 volts | Single-phase or three-phase, commonly 208Y/120 or 480Y/277 volts |
| Generator size | Sized for a house: essentials or the whole home | Sized from a load study of the building's equipment, often much larger |
| Fuel | Natural gas or propane | Natural gas, propane or diesel with on-site fuel storage |
| Transfer switch | One automatic transfer switch at the home's panel | One or more automatic transfer switches, often separating critical and non-critical loads |
| Power distribution | Feeds the home's main panel | Feeds switchgear, distribution panels, subpanels and transformers |
| Code category | Optional standby (NEC Article 702) | Optional standby, or emergency and legally required systems (NEC 700 and 701) when required |
| Testing | Automatic exercise per the manufacturer | Scheduled exercise and testing; required systems follow NFPA 110 |
| Installation | Concrete pad beside the house | Pad or enclosure sized to the unit, fuel supply, conduit runs and sometimes crane placement |
Looking for a generator for your home?
Most commercial buildings run on three-phase power, and their motors, compressors, HVAC and production equipment need it. We install three-phase generators matched to your service voltage, then build the distribution that gets backup power where it needs to go.

The National Electrical Code sorts backup power into three categories. The category sets how fast power must return and how the system is wired, tested and maintained. We’ll help you determine what applies.
Required by code to protect lives: egress lighting, exit signs, fire alarms, fire pumps and similar loads.
NEC Article 700 · power within 10 seconds
Required by code to prevent hazards or support rescue: ventilation, smoke removal, sewage and critical processes.
NEC Article 701 · power within 60 seconds
Chosen by the business to avoid lost revenue and spoiled inventory: refrigeration, HVAC, data and operations.
NEC Article 702 · most business generators
Lost sales, idle staff and spoiled inventory add up fast. Run your own numbers to see what a few outages a year really cost your business.
Then compare that with a standby generator that turns your power back on automatically, in seconds.
Enter your own numbers. The results update as you type.
A simple estimate from your inputs. It doesn't include harder-to-measure costs like lost customers, data loss or equipment damage from power surges when the grid returns.
We review your service, equipment and which loads must stay on.
Generator size, voltage, fuel, transfer switches and distribution planned.
You get a written, flat-rate price for the complete system.
We pull permits and coordinate fuel, pad and utility requirements.
Generator, transfer switches, feeders and distribution installed.
Startup, transfer testing under load and a walkthrough for your staff.
A generator that won’t start during an outage is worth nothing. Regular testing and service keep it ready.
Generators need to run regularly. NFPA 110 calls for monthly exercise of at least 30 minutes for systems that fall under it.
Generators that run lightly loaded during exercise can be tested with a load bank to prove they’ll carry the building.
We inspect and test automatic transfer switches so the handoff happens when the power fails.
We handle the generator, transfer switches and every panel, feeder and transformer behind them, so nothing falls between contractors.
Florida State Certified Electrical Contractor EC13004667 with a $2 million insurance policy and a Jacksonville office.
Written, flat-rate pricing before work begins and a five-year warranty on our workmanship.
Yes. We install three-phase standby generators matched to your service, commonly 208Y/120 or 480Y/277 volts, along with the transfer switches and distribution they connect to.
Commercial systems are usually larger, often three-phase, may run on diesel as well as gas, and can include multiple transfer switches and distribution panels. Some commercial systems are also required by code and must meet stricter testing rules.
It depends on the equipment you need to keep running. We start with a load study of your service and critical equipment, then size the generator and transfer switches to match.
Yes. Many businesses back up only critical loads such as refrigeration, servers, security and some lighting. We separate those circuits so a smaller generator can carry them.
Florida law requires many motor fuel stations, including newer or substantially renovated stations and certain stations near evacuation routes, to be prewired with a transfer switch for generator power. Call us and we’ll review your site.
Regularly. For systems that fall under NFPA 110, that means monthly exercise of at least 30 minutes, plus scheduled maintenance. We can set up a testing and maintenance plan.
Call or request a free estimate online. We’ll study your loads and design a standby system with a written, upfront price.
(904) 365-7777
service@empireelec.com
5810 Macy Ave, Jacksonville, FL 32211
Mon–Fri, 8:00 am–4:00 pm · 24/7 emergency service