Larger buildings run on more than one voltage. Heavy equipment and lighting run at 480 or 277 volts, while transformers step power down to 208/120 volts for receptacles and office equipment. Empire Electric’s commercial electricians design, install and troubleshoot every part of that system.

Distribution Design

Panels, feeders, transformers

Multiple Voltages

480, 277, 208 and 120 volts

Phase Balancing

Loads spread across all three phases

Troubleshooting

Overheating, imbalance, trips

One Building. Four Voltages. Two Phases.

Most commercial buildings take power at 480Y/277 volts, feed heavy equipment and lighting directly, and use step-down transformers to create 208Y/120 volts for everything else.

Trace the Power Through a Commercial Building

Pick a piece of equipment to see the voltage it needs and the path power takes to reach it.

480V277V208V120V

Step-Down Transformers Sized for Your Building

A step-down transformer converts 480-volt power to 208Y/120 volts for receptacles, office equipment and smaller loads. Size it too small and it overheats; size it too large and you pay for capacity you’ll never use.

Transformer Size Estimator

Estimate the step-down transformer for your 208Y/120-volt loads.

–calculated load (kVA)
–suggested standard size
–approximate 480V primary current

Estimate only: kVA = 208 V × amps × 1.732. Actual sizing follows an NEC load calculation, transformer overcurrent protection rules (NEC 450.3) and the design professional's specifications.

Commercial Distribution Is a Different World

Residential versus commercial electrical systems
Typical HomeCommercial Building
Service voltage120/240V single-phase480Y/277V or 208Y/120V three-phase
TransformersNone in the buildingStep-down transformers and separately derived systems
PanelsOne main panel, maybe a sub-panelSwitchboards, distribution panels and multiple panelboards
LoadsAppliances and A/CMotors, rooftop units, kitchens, servers and 277V lighting
GroundingSingle service groundBonding and grounding for every transformer secondary
DocumentationBasic panel labelsPanel schedules, one-line diagrams and arc-flash labels

Commercial electricians for commercial systems

A great residential electrician may never have worked on a 480-volt switchboard or bonded a transformer secondary. Our commercial electricians do this every week, so we send them for every distribution job.

Commercial Distribution Services

Distribution Design

Panel layouts, feeder sizing and transformer selection, coordinated with your engineer or design-build.

Sub-Panel Installation

New panelboards for tenant spaces, additions, equipment rooms and floors.

Transformer Installation

Step-down transformers installed, bonded, grounded and protected to code.

Load and Phase Balancing

Loads spread evenly across phases to reduce heating and nuisance trips.

Equipment Feeders

Power for rooftop units, compressors, kitchens, elevators and production equipment.

Panel Schedules and Labeling

Accurate, up-to-date panel schedules and labels your facility team can rely on.

When Distribution Problems Show Up

Our commercial troubleshooters find the cause, from a failing transformer to an overloaded phase.

Hot or Noisy Transformers

Phase Imbalance

Nuisance Breaker Trips

Lost Phase or Single Phasing

Flickering 277V Lighting

Wrong Voltage at Equipment

Neutral and Grounding Problems

Overloaded Sub-Panels

Designed, Installed and Documented

01

Survey

We review the existing service, panels and loads, plus any drawings.

02

Design

We plan panels, feeders and transformers, or build from your engineer’s plans.

03

Permit

We pull permits and coordinate shutdowns around your operations.

04

Install

Our commercial crews install, terminate, bond, ground and label.

05

Test and Document

We verify voltages and rotation and update panel schedules.

Sub-Panel and Transformer Questions

Why do commercial buildings use more than one voltage?

Higher voltage like 480 volts moves large amounts of power efficiently to motors, rooftop units and lighting. Receptacles and office equipment need 120 volts, so step-down transformers create a 208Y/120-volt system for them.

What does a step-down transformer do?

It converts the building’s 480-volt power to 208Y/120 volts, creating a new electrical system that must be properly bonded, grounded and protected.

Is 208 volts the same as 240 volts?

No. Commercial 208-volt power comes from a three-phase system. Equipment designed for 240 volts may run hotter or weaker on 208 volts, so we confirm ratings before connecting.

Why does phase balance matter?

Uneven loads across phases can overheat transformers and neutrals and cause nuisance trips. We balance loads when installing and can rebalance existing panels.

Can you work from our engineer's drawings?

Yes. We build from engineered plans, and we can also handle design-build for many tenant and equipment projects.

Can you replace a failing transformer?

Yes. We troubleshoot, size and replace transformers and coordinate shutdowns to limit downtime.

Power Every Voltage in Your Building

Call or request a quote. Our commercial electricians will design, install or troubleshoot your panels and transformers.

(904) 365-7777

service@empireelec.com

Office

5810 Macy Ave, Jacksonville, FL 32211

Hours

Mon–Fri, 8:00 am–4:00 pm · 24/7 emergency service