Florida Certified EC13004667Veteran-OwnedNo-Commission Electricians

Emergency and Egress Lighting in Jacksonville

When the power fails, emergency lights and exit signs guide everyone out safely. Empire Electric installs, tests, repairs and upgrades emergency lighting and exit signs for businesses, warehouses, apartment communities and public buildings across Jacksonville and Northeast Florida, built to the Life Safety Code your fire marshal inspects to.

Emergency Lighting for a Egress Door
Licensed Contractor

Florida Certified EC13004667

Insured

$2 million policy

Code-Focused

Built to NFPA 101

90-Minute Testing

Verified, documented

Upfront Pricing

Written, flat-rate estimates

24/7 Emergency

Failed units fixed fast

Emergency Lighting for Every Building

Choose your building type to see how we help.

Offices and Retail

Exit signs and emergency lights along corridors, stairs and exits so staff and customers can find their way out.

Warehouses and Industrial

Emergency lighting for long aisles, high ceilings and large open floors, including battery-backed high bays.

Apartments, Condos and HOAs

Stairwells, corridors, clubhouses and exterior exit paths kept lit and inspection-ready.

Schools, Churches and Assembly

Clear egress lighting for classrooms, sanctuaries, gyms and event spaces full of people.

Failed a fire inspection?

We correct emergency lighting and exit sign deficiencies quickly and document the work for your re-inspection.

What the Life Safety Code Requires

Florida enforces emergency lighting through the Florida Fire Prevention Code, which adopts NFPA 101, the Life Safety Code. Here are the core requirements we design and test to.

90 min

Minimum emergency lighting duration when normal power fails

1 fc

Average light at floor level along the exit path, with no point below 0.1 fc

10 sec

Automatic transfer to emergency lighting after power is lost

40:1

Maximum ratio of brightest to dimmest point along the path

Required testing

Battery-powered emergency lights and exit signs must be tested on a schedule, with written records kept for your fire inspector.

Figures from NFPA 101, Section 7.9. At the end of the 90 minutes, light levels may decline to an average of 0.6 fc and a minimum of 0.06 fc. Your local fire marshal is the final authority and may have additional requirements.

Emergency Lighting and Exit Sign Services

LED Exit Signs

Emergency Light Units

Exit and Emergency Combo Units

Remote Emergency Heads

Self-Testing Units

Monthly and Annual Testing

Battery and Lamp Replacement

Fire Inspection Corrections

Is Your Building Inspection-Ready?

Fire inspectors regularly cite dead batteries, missing test logs and dark exit paths. Run through this quick check to spot problems before they do.

Not sure about an item? That’s a sign it’s time for a professional inspection and 90-minute test.

Emergency Lighting Self-Check

Check each item that's true for your building today.

0 of 8 checkedStart checking items to see where your building stands.
Schedule an Inspection

Standard or Self-Testing Units?

Both meet code when they’re maintained. The difference is who does the testing and how quickly problems are found.

Standard Units

Someone presses the test button on every unit each month and runs a 90-minute test each year, then records the results.

Self-Testing Units

Units run their own scheduled tests and show a fault indicator when a battery, lamp or charger fails.

Our Emergency Lighting Process

01

Egress Survey

We walk every exit path, stairwell and exit discharge and check existing units.

02

Layout and Coverage

We plan unit locations to meet light levels and exit sign visibility.

03

Upfront Price

You get a written, flat-rate price before work begins.

04

Installation

Units, signs and circuits installed, with permits pulled when required.

05

90-Minute Verification

We test the system and confirm it lights the path for the full duration.

06

Records and Ongoing Testing

You get documentation, and we can handle monthly and annual testing.

Life Safety Lighting You Can Trust

Built to Pass Inspection

We design and test to the Life Safety Code and correct fire inspection deficiencies, with documentation for your records.

One Vendor for Every Property

Property managers can put emergency lighting testing and repairs for their whole portfolio in one place.

Upfront Pricing and a Warranty

Written, flat-rate pricing before work begins and a five-year warranty on our workmanship.

Emergency Lighting Questions

What is egress lighting?

Egress lighting lights the path people use to leave a building: corridors, aisles, stairs, ramps and the exit discharge outside. Emergency lighting keeps that path lit when normal power fails.

How long do emergency lights have to stay on?

The Life Safety Code requires emergency lighting to operate for at least 90 minutes after normal power fails.

How often do emergency lights and exit signs need to be tested?

Battery-powered units need a 30-second functional test every month and a full 90-minute test every year, with written records of each test.

Do I need emergency lighting in my building?

Most commercial, assembly, educational and multi-family buildings require it along exit paths. Your fire marshal decides for your building, and we can review what your space needs.

Can you fix emergency lighting violations from a fire inspection?

Yes. Send us your inspection report and we’ll correct the emergency lighting and exit sign items, then document the work for your re-inspection.

Can my regular light fixtures double as emergency lights?

Often, yes. Many fixtures, including LED high bays and troffers, can be fitted with battery backup drivers so they keep working when the power goes out.

Keep Every Exit Lit

Call or schedule an inspection online. We’ll test your emergency lights and exit signs, fix what’s failing and give you a written, upfront price.

(904) 365-7777

service@empireelec.com

Office

5810 Macy Ave, Jacksonville, FL 32211

Hours

Mon–Fri, 8:00 am–4:00 pm · 24/7 emergency service